Product info   
Search
Your location:home > News > Product info >

10kV sample of YKK series

2020-05-12 09:51      Click:times
1. Overview
YKK series 10kV High voltage three-phase asynchronous motor is a closed air-to-air cooling cage type asynchronous motor. The protection grade of this series of motors is IP44 or IP54 (GB / T 4942.1), which can be used in dusty or humid environment, and can also provide higher protection grade according to the user's requirements. The design of this series of motors adopts F-class insulation, and the temperature rise is assessed according to B-class (80K), which increases the reliability of the motor operation, improves the service life of the motor, and also provides a higher level of insulation design according to the user's requirements.
This series of motors have the advantages of high power index, low noise, small vibration, reliable operation, convenient installation and maintenance.
2. Purpose
This series of motors can be used to drive all kinds of machines, such as compressors, pumps, crushers, cutting machine tools, transportation machinery and other mechanical equipment, and used as the prime mover of various industrial and mining enterprises, such as mines, power plants, petroleum, chemical industry, etc. The motors for driving blowers, coal mills, rolling mills, hoists and belt conveyors shall be provided with relevant technical data when ordering, and a technical agreement shall be signed as the basis for the special design of the motors, so as to ensure the reliable operation of the motors.
3. Structure
This series of motor base adopts the box structure welded with steel plate, which is light in weight and good in rigidity. The side and top of the base are installed with removable cover plate, which is convenient for the maintenance of the motor.
The stator adopts the external pressure mounting structure, the end of the stator winding is reliably fixed. During the manufacturing process, it has undergone many turns to turn impulse voltage tests and ground withstand voltage tests, and it has been treated by the vacuum pressure impregnation solventless paint (VPI) process to ensure the excellent insulation performance, mechanical strength and moisture-proof ability of the motor.
The squirrel cage rotor adopts reliable welding technology, excellent rotor processing and manufacturing technology, and is fastened in the groove.
There are two types of motor bearings in this series, rolling bearing and sliding bearing, which are determined by motor power and speed.
The protection grade of the main outlet box of this series of motors is IP54, which is generally installed on the right side of the motor (as viewed from the motor shaft extension end), or on the left side of the motor according to the order requirements. There are independent terminals inside and outside the main outlet box. The main outlet box can be rotated with an interval of 90 degrees, so that cables can be led in from up, down, left and right directions.
4. See Table 1 for technical data.
5. See Table 2 for external installation dimensions
6. Model description:  YKK (Motor series code, squirrel-cage motor with an air-air cooler)      4501 (The center height of the frame is 450mm, and the no. 1 iron core is long)    --    4  (Motor pole number,4 pole)
7. Precautions for ordering (please indicate the following parameters when ordering):
Example: motor model: ykk4501-4 installation method: IMB3
Rated power: 315KW protection class: IP44 or IP54
Rated voltage: 10000v cooling mode: ic611
Rated frequency: 50Hz environmental condition: altitude 1000m, ambient temperature 40 ℃
Insulation grade: grade F rotation direction: clockwise rotation (looking at the motor shaft extension end)
Synchronous speed: 1500r / min outlet box position: right side of motor facing motor shaft extension end)
Note 1: 4-pole motor cannot be driven by pulley; if other pole numbers need to be driven by pulley, consult with the manufacturer in advance.
Note 2: it is recommended that the user check that the moment of inertia of the rotating part of the driven mechanical equipment (after conversion to the motor speed) should not exceed the value of "load J" in the technical data sheet;
Note 3: the user grid shall ensure that the motor terminal voltage is not less than 85% of the rated voltage during the starting process of the motor;
Note 4: the resistance moment characteristic of the driven machinery is the motor of water pump and blower. It is allowed to start twice continuously in the actual cold state or once in the hot state of the motor. The motor needs to stop naturally between the two starts. The additional restart motor should stop 4 hours later.
Note 5: if the user needs the moment of inertia of the rotating part of the machinery driven by the motor to exceed the value of "load J" in the technical data sheet, or requires the motor to be started frequently, please contact and negotiate with the manufacturing company in advance, so that the special design can ensure the reliable operation of the motor.
Note 6: with the technical progress and the modification of relevant domestic and foreign standards, the dimensions and technical parameters in the sample are subject to change without notice. Please ask our company for the formal outline drawing after ordering.
   
Table 1 technical data of YKX series 10kV motor (guaranteed value)
Model rated power rated voltage rated current Rated speed Efficiency power factor Tm/Tn Tst/Tn Ist/In Moment of inertia weight
kw kv A r / min % COSΦ motor J
kg·m²
load J
kg·m²
kg
YKX4501-4 315 10 23 1490 92.1 |0.86 1.8 |0.7 7 11.3 177 3550
YKK 4502-4 355 10 25.8 1490 92.3 0.86 1.8 |0.7 7 12.2 197 3625
YKI 4503-4 400 10 29 1490 92.5 0.86 1.8 0.7 7 12.5 199 3680
YKK4504-4 450 10 32.6 1490 92.7 0.86 1.8 |0.7 7 13.7 219.5 |3795
YKX 4505-4 500 10 36.1 1490 92.9 0.86 1.8 0.7 7 14.5 235.5 3840
YKK 4506-4 560 10 39.9 1489 93.1 0.87 1.8 0.7 1 14.8 243 3925
YKI5001-4 630 10 44.8 1493 93.3 0.87 1.8 0.7 7 24 310 4800
YKK 5002-4 710 10 50.3 1493 93.6 |0.87 1.8 0.7 1 27 355 4950
YII5003-4 800 10 55.9 1493 93.9 0.88 1.8 0.7 1 29 381 5100
YKK 5004-4 900 10 62.7 1493 94.1 0.88 1.8 0.7 7 31 418 5300
YEK5005-4 1000 10 69.6 1493 94.3 0.88 1.8 0.7 7 34 471 5400
YKK5601-4 1120 10 76.9 1490 94.5 0.89 1.8 0.1 1 46.8    
YKK5602-4 1250 10 85.1 1490 94.6 0.89 1.8 0.1 1 51.5    
YKE5603-4 1400 10 95.9 1490 94.7 0.89 1.8 0.6 1 56.5    
YKK 6301-4 1600 10 109 |1495 95 |0.89 1.8 0.6 7 97    
TKK 6302-4 1800 10 122.8 1495 95.1 |0.89 1.8 0.6 7 108    
YKK 6303-4 2000 10 136 |1495 |95.2 0.89 1.8 0.6 7 121    
TKI4503-6 280 10 21.4 993 92 0.82 1.8 0.1 6 19 520 3895


Table 1 (Continued) technical data of 10kV motor of YKK series (guaranteed value)
                         
Model rated power rated voltage rated current Rated speed Efficiency power factor Tm/Tn Tst/Tn Ist/In Moment of inertia weight
kw kv A r / min % COSΦ motor J
kg·m²
load J
kg·m²
kg
YKK5004-8 400 10 31.9 745 92.8 0.78 1.8 0.7 6 50    
YKK5005-8 450 10 35.3 745 93.1 0.79 1.8 0.7 6 53    
YKK5006-8 500 10 39.1 745 93.4 0.79 1.8 0.7 6 54.5    
YKK5601-8 560 10 42.6 745 93.6 0.81 1.8 0.7 6 71    
YKK5602-8 630 10 47.9 745 93.7 0.81 1.8 0.7 5 78    
YKK5603-8 710 10 54 745 93.8 0.81 1.8 0.7 6 83    
YKK5604-8 800 10 60.7 745 93.9 0.81 1.8 0.7 6 89.8    
YKK 6301-8 900 10 67.3 745 94.2 0.82 1.8 0.7 6 130    
YKK 6302-8 1000 10 74.7 745 94.3 0.82 1.8 0.7 6 140    
YKK6303-8 1120 10 83.5 745 94.4 0.82 1.8 0.7 6 155    
YKK 5001-10 200 10 17.6 595 90.9 0.73 1.8 0.7 5.5 45.5    
YKK5002-10 220 10 19 595 91.4 0.73 1.8 0.7 5.5 49    
YKK5003-10 250 10 21.3 595 91.7 0.74 1.8 0.7 5.5 50    
YKK5004-10 280 10 23.8 595 91.9 0.74 1.8 0.7 5.5 53    
YKK 5005-10 315 10 26.3 595 92.3 0.75 1.8 0.7 5.5 57    
YKK5006-10 355 10 29.5 595 92.5 0.75 1.8 0.7 5.5 59    
YKK5601-10 400 10 32.8 595 92.7 0.76 1.8 0.7 6 90    
YKK 5602-10 450 10 36.8 595 92.8 0.76 1.8 0.7 6 96    


Table 1 technical data of YKX series 10kV motor (guaranteed value)
Model rated power rated voltage rated current Rated speed Efficiency power factor Tm/Tn Tst/Tn Ist/In Moment of inertia weight
kw kv A r / min % COSΦ motor J
kg·m²
load J
kg·m²
kg
YKK4504-6 315 10 24.1 993 92.2 0.82 1.8 0.7 6 20.7 614 4030
YKX4505-6 355 10 27 993 92.5 0.82 1.8 0.7 6 22.8 753 4205
YKK4506-6 400 10 30 993 92.7 0.83 1.8 0.7 6 23.7 818 4280
YKK5001-6 450 10 33.7 994 93 0.83 1.8 0.7 6 32 680 4950
YKK5002-6 500 10 36.9 994 93.2 0.84 1.8 0.7 6 34 755 5100
YKK5003-6 560 10 41.2 994 93.5 0.84 1.8 0.7 6 36 793 5250
YKK5004-6 630 10 46.1 993 93.9 0.84 1.8 0.7 6 39 847 5400
YKE5005-6 710 10 51.9 993 94 0.84 1.8 0.7 6 42 919 5550
YKK5601-6 800 10 57.7 990 94.2 0.85 1.8 0.7 6 76    
YKK5602-6 900 10 64.8 990 94.3 0.85 1.8 0.7 6 82.5    
YKK5603-6 1000 10 72 990 94.4 0.85 1.8 0.7 6 86    
YKX5604-6 1120 10 80.5 990 94.5 0.85 1.8 0.7 6 93    
YKX6301-6 1250 10 88.5 990 94.8 0.86 1.8 0.7 6 121    
YKK6302-6 1400 10 99 990 94.9 0.86 1.8 0.7 6 135    
TKK6303-6 1600 10 113.1 990 95 0.86 1.8 0.7 6 151    
YK5001-8 280 10 22.8 745 92.2 0.77 1.8 0.7 6 42    
TKK5002-8 315 10 25.6 745 92.3 0.77 1.8 0.7 6 45.5    
YKK5003-8 355 10 28.4 745 92.6 0.78 1.8 0.7 6 48    


Table 1 technical data of YKX series 10kV motor (guaranteed value)
Model rated power rated voltage rated current Rated speed Efficiency power factor Tm/Tn Tst/Tn Ist/In Moment of inertia weight
kw kv A r / min % COSΦ motor J
kg·m²
load J
kg·m²
kg
TKX5603-10 500 10 40.9 595 92.9 0.76 1.8 0.7 6 99    
YKL5604-10 560 10 45.7 595 93 0.76 1.8 0.7 6 105    
TKK5605-10 630 10 51.4 595 93.1 0.76 1.8 0.7 6 114    
YKX6301-10 710 10 57 595 93.4 0.77 1.8 0.7 6 140    
YKK6302-10 800 10 64.2 595 93.5 0.77 1.8 0.7 6 153    
TKI6303-10 900 10 72.1 595 93.6 0.77 1.8 0.7 6 165    
YKK6304-10 1000 10 80 595 93.7 0.77 1.8 0.7 6 183    
YEI5601-12 280 10 24.8 495 91.7 0.69 1.8 0.7 6 99    
YKE5602-12 315 10 27.9 495 91.8 0.71 1.8 0.7 6 105    
YKK5603-12 355 10 31.4 495 91.9 0.71 1.8 0.7 6 114    
YKK5604-12 400 10 35.4 495 92 0.71 1.8 0.7 6 123    
YKK5605-12 450 10 39.7 495 92.2 0.71 1.8 0.7 6 126    
YKE6301-12 500 10 44 495 92.5 0.71 1.8 0.7 6 140    
YKK6302-12 560 10 49.2 495 92.6 0.71 1.8 0.7 6 152    
YKX6303-12 630 10 55.3 495 92.7 0.71 1.8 0.7 6 166    
YEI6304-12 710 10 62.2 495 92.8 0.71 1.8 0.7 6 183    

TAG: